| Character |
Significance |
Requirements |
| PPS000 |
The injection molding compound must be PPS-based. This is the generic PPS family designation. |
Currently, the callouts for all PPS injection molding compounds start with "PPS000." |
| G |
Type of reinforcements and/or fillers: "G" for glass fiber "C" for carbon or graphite fiber "M" for mineral fillers "L" for lubricants "R" for mixtures of fillers and reinforcements |
The letter in the callout of the Ryton® PPS compound must match the letter in the callout on the drawing or specification. |
| 40 |
Nominal filler content in weight percent within the following tolerance ranges: ± 2 wt. % for < 15% glass fiber "G" ± 3 wt. % for > 15% glass fiber "G" ± 2 wt. % for carbon or graphite fiber "C" ± 2 wt. % for mineral fillers "M" ± 3 wt. % for mixtures of fillers "R" (Tolerance ranges for lubricant content must be established by agreement between the supplier and the user.) |
The filler content given in the callout of the Ryton® PPS compound must be within the specified tolerance range of the filler content given in the callout on the drawing or specification. |
| A |
References Physical Properties Requirements Table A in the ASTM D4067 Standard. |
All ASTM D4067 callouts should have the character "A" in the tenth position. |
| 5 |
Minimum Tensile Strength requirement according to performance levels defined in Table A in the ASTM D4067 Standard. |
The number in the callout of the Ryton® PPS compound must be greater than or equal to the number given in the callout on the drawing or specification. |
| 3 |
Minimum Flexural Modulus requirement according to performance levels defined in Table A in the ASTM D4067 Standard. |
The number in the callout of the Ryton® PPS compound must be greater than or equal to the number given in the callout on the drawing or specification. |
| 3 |
Minimum Notched Izod Impact Strength requirement according to performance levels defined in Table A in the ASTM D4067 Standard. |
The number in the callout of the Ryton® PPS compound must be greater than or equal to the number given in the callout on the drawing or specification. |
| 4 |
Minimum Flexural Strength requirement according to performance levels defined in Table A in the ASTM D4067 Standard. |
The number in the callout of the Ryton® PPS compound must be greater than or equal to the number given in the callout on the drawing or specification. |
| 3 |
Minimum Density requirement according to performance levels defined in Table A in the ASTM D4067 Standard. |
The number in the callout of the Ryton® PPS compound must be greater than or equal to the number given in the callout on the drawing or specification. |